Product Supply Code: AR515
Product Name: Fault Finding in Control Systems
Tender Supply Category: Automation Robotics and Control Laboratory
Fault Finding in Control Systems
Manufacturers and Suppliers IndiaFault Finding in Control Systems A circuit with a collecting tank, pump and graduated tank is provided for control of level and flow rate. A pneumatic control valve is used as the actuator. There is a valve in the tank outlet to generate a disturbance variable in level control. Cascade control is possible whereby the level in the tank is controlled by way of the flow rate. Two circuits are used in the control of the temperature. A refrigeration system cools the water in the collecting tank. A pump circulates the water via a heat exchanger (cooling circuit). A heater heats the water in the graduated tank. Another pump also circulates the warm water via the heat exchanger. In the heat exchanger the water in the cooling circuit is heated. The controlled variable is the temperature of the water in the cooling circuit after heating in the heat exchanger. The actuator is the pneumatic control valve which adjusts the flow rate of the warm water. Cascade control is also possible to control the temperature. Control of level, flow rate, temperature and cascade control Main circuit with collecting tank, graduated stirred tank with heater, pneumatic control valve and centrifugal pump Cooling circuit with pump, heat exchanger and rotameter Refrigeration system and pump to cool the water in the collecting tank Pneumatic control valve in main circuit as actuator for all controls Sensors for the measurement of the controlled variables; level, flow rate and temperature 2 parameter is able industrial controllers 6 pushbuttons for fault simulation PLC to monitor safety devices Process control software via PCIe under Windows 7, 8.1, 10 including PC1 Computer-System with 21" TFT-Monitor Win 10 engl. Technical Data: Tanks Stirred tank with scale: 7l Collecting tank: 90l Main circuit centrifugal pump Flow rate: 75l/min Head: 20m 2 pumps, cooling circuit and refrigeration system Flow rate: 60l/min Head: 4m Heater power output: 2kW Controller parameterisable as - P, PI or PID controller Measuring ranges Level: 0...350mm Flow rate: 0...1999l/h Temperature: 0...100°C 230V, 50Hz, 1 phase
Fault Finding in Control Systems Quality Assurance: We being a leading Fault Finding in Control Systems manufacturer from India. NaugraLabEquipments are actively involved in providing precision equipments of premium quality to clients across the globe for Testing Lab and TVET Technical Lab, Industial Training Institutions. We always utilize the most advanced and sophisticated technology for production process of Fault Finding in Control Systems and supply exceptional range of other products like Fault Finding in Control Systems for tender supply from India.